<
From version < 18.1 >
edited by Fredrik Lagerström
on 2021/04/07 11:53
To version < 19.1
edited by Fredrik Lagerström
on 2021/04/07 11:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -18,8 +18,15 @@
18 18  
19 19  [[image:1614600482879-412.png]]
20 20  
21 -For user-defined prestressed reinforcement of Wire and Single wire types, it is possible to set a reinforcement diameter of the following dimensions.
22 22  
22 +
23 +(% class="table-hover" %)
24 +|(% style="background-color:#0076cb" %)(% style="color:#ffffff" %)**Bar type**|(% style="background-color:#0076cb" %)(% style="color:#ffffff" %)**Picture**|(% style="background-color:#0076cb" %)(% style="color:#ffffff" %)**Description**|(% style="background-color:#0076cb" %)(% style="color:#ffffff" %)**Also known as**
25 +|Wire|[[image:https://www.theepdregistry.com/wp-content/uploads/f89.jpg||alt="PC-strand – Prestressed steel for reinforcement of concrete | The EPD Registry™ | The World EPD Library and Digital Databases for Construction Products" height="175" width="185"]]|Used for prestressing steel. Several single wires bundled to form a bigger wire.|
26 +|Single Wire| |Used for prestressing steel|
27 +
28 +For predefined materials a specific set of wires are used with specific areas. That is why a user-defined material and a predefined material may have different cross section areas. For user-defined prestressed reinforcement of Wire and Single wire types, it is possible to set a reinforcement diameter of the following dimensions.
29 +
23 23  (% class="table-condensed" style="width:1193px" %)
24 24  |(% style="background-color:#0076cb; text-align:right; width:109px" %) |(% colspan="27" rowspan="1" style="background-color:#0076cb; text-align:center; vertical-align:middle; width:42px" %)(((
25 25  (% style="color:#ffffff" %)**Area of wire**
... ... @@ -34,13 +34,6 @@
34 34  
35 35  (% style="color:#c0392b" %)**!**(%%)// Note that the areas in the table above may be different from predefined areas for predefefined materials!//
36 36  
37 -For predefined materials a specific set of wires are used with specific areas. that is why a user defined material and a predefined material may have different cross section areas.
38 -
39 -(% class="table-hover" %)
40 -|(% style="background-color:#0076cb" %)(% style="color:#ffffff" %)**Bar type**|(% style="background-color:#0076cb" %)(% style="color:#ffffff" %)**Picture**|(% style="background-color:#0076cb" %)(% style="color:#ffffff" %)**Description**|(% style="background-color:#0076cb" %)(% style="color:#ffffff" %)**Also known as**
41 -|Wire|[[image:https://www.theepdregistry.com/wp-content/uploads/f89.jpg||alt="PC-strand – Prestressed steel for reinforcement of concrete | The EPD Registry™ | The World EPD Library and Digital Databases for Construction Products" height="175" width="185"]]|Used for prestressing steel. Several single wires bundled to form a bigger wire.|
42 -|Single Wire| |Used for prestressing steel|
43 -
44 44  = Material libraries =
45 45  
46 46  == Sweden ==
Copyright 2020 StruSoft AB
PRE-Stress Documentation